INDICO Indirect air cooling system

INDICO Indirect air cooling system

INDICO indirect air-cooling system is a standardised multi-component dry air-cooling system, consisting of a chiller, a thermal carrier (water-glycol) and heat exchangers. The system is designed to deliver conditioned inlet air to achieve optimal house temperature in hot and/or humid ambient climate.

An optimized house climate protects the animals from heat stress, improves feed conversion and lowers mortality during hot and humid periods. The system is applicable to closed housing for any kind of livestock (CowsPoultryPigs and even Insects).

Indico-schematic-1-1030x438.jpeg

The INDICO system consists of the following key components:

  • Chiller(s)
  • Filters (skid)
  • Buffer tank
  • Pumps (skid)
  • Valves (skid)
  • Heat exchangers
  • Piping
  • Sensors
  • Cabling
  • Remote accessible visual control & monitoring

Pumps, valves and filters are preassembled onto standardized skids. These skids are delivered to the site as a single unit. The whole system is easy to install, can be assembled on-site and integrated into the house, where the skids and buffer tank are to be placed in an indoor technical room.

The INDICO system is available in cooling capacities ranging from 75kWth up to 3.2MWth. Larger can be handled by multiple individual systems in parallel. It is scalable up to five individually controlled sections by means of motorized valves on an extension skid. A combination with the Triple EEE heat recovery system for preconditioning air during wintertime is also available.

INDICO-chiller.jpeg

INDICO-exchanger.jpeg

INDICO-skid.jpeg

INIDCO-Buffer-tank.jpeg

Working principle of the cooling system

The schematic below shows the basic working principle and main components of the INDICO system for cooling two houses/sections:

  • coolant (water or preferably a water-glycol mixture) circulates in a primary circuit between a cooling machine and the buffer tank by means of a pump (could be either external or integrated in the cooling machine).
  • A filter is integrated in the primary circuit – in the supply to the cooling machine – to protect the cooling machine from large particles that could block the coolant flow.
  • The chiller cools by means of a refrigerant vapour-liquid compression/expansion cycle – the coolant to a preferred temperature of 9 degrees Celsius.
  • The cooling machine via an integrated temperature sensor in the primary circuit controls the exiting coolant temperature.

Indico-schematic-2-1030x569.jpeg

  • secondary pump on the ‘pump skid’ circulates the coolant between the buffer vessel and the inlet heat exchangers of the different houses/sections.
  • The inlet air temperature of each house is controlled by a system controller, to preferably 17 degrees Celsius – by means of coolant flow control and a temperature sensor in the inlet air.
  • Coolant flow is controlled per house/section by means of the speed of the secondary pump on the ‘pump skid’ and by means of the motorized valves in the return line on the ‘valve skid’.
  • The inlet air passes through the inlet heat exchanger and cools from ambient temperature to the preferred target of 17 degrees Celsius. Depending on ambient air condition, water vapour condenses from the air and forms condensate in the heat exchanger. Depending on the climate/humidity, the amount of condensate can be substantial.
  • The system is controlled with sensors to monitor coolant flow and supply and return temperatures per house/section and with energy monitoring for the pumps and cooling machine.
  • Data collected by sensors is used to calculate system efficiency, monitor annual power consumption, and evaluate nominal system operation.
  • Collected data from sensors is stored locally in the controller (SD card) and is accessible and downloadable through the IXON online portal of Inno+ (when an internet...